GENERATOR SETS POWERED BY YANMAR ENGINE
MAIN SPECIFICATION OF GENERATING SETS(50Hz) | |||||||||
GENSET MODEL | GFS-YM7 | GFS-YM8.5 | GFS-YM10 | GFS-YM12 | GFS-YM16 | GFS-YM25 | GFS-YM32 | GFS-YM40 | GFS-YM45 |
Continuous output(kw/kva) | 7/8.7 | 8.5/10.6 | 10/12.5 | 12/15.0 | 16/20 | 25/31.3 | 32/40 | 40/50 | 45/56 |
Standby output(kw/kva) | 7.7/9.6 | 9.35/11.7 | 11/13.75 | 13.2/16.5 | 17.6/22 | 27.5/35 | 35.2/44 | 44/55 | 49.5/62 |
Rating Definitions
Continuous Power Model P with no Suffix
These ratings are applicable for supplying continuous electrical (at variable load) in lieu of commercially purchased power .there is no limitayion to the
annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Standby power Model P with no Suffix(S)
These ratings are applicable for supplying continuous electrical (at variable load) in the event of a utility power failure . No overload is permitted on these
ratings. The alternator on this model is peak continuous rated (as defind in ISO8528-3) AT27℃
TECHNICAL DATA(50Hz) | |||||||||
DIESEL ENGINE MODEL | 3TNV76 | 3TNV82A | 3TNV88 | 3TNV84T | 4TNV84T | 4TNV98 | 4TNV98T | 4TNV106 | 4TNV106T |
Engine characters | Vertical type,4-stroke,water cooled,1500RPM | ||||||||
Standby output(KW) | 9 | 11 | 13.5 | 15.8 | 21.3 | 34.6 | 41.9 | 49.4 | 56 |
Aspiration | Natural | Turbo | Turbo | Natural | Turbo | Natural | Turbo | ||
Bore(mm)*stroke(mm) | 76×82 | 82×84 | 88×90 | 84×90 | 84×90 | 98×110 | 98×110 | 106×125 | 106×125 |
NO.of cylinder | 3 | 3 | 3 | 3 | 4 | 4 | 4 | 4 | 4 |
Displacement (lit) | 1.116 | 1.33 | 1.642 | 1.496 | 1.995 | 3.318 | 3.318 | 4.412 | 4.412 |
Cooling system | Radiator | ||||||||
Combustion | IDI | Direct injection | |||||||
Starting System | Electric | ||||||||
ALTERNATOR MODEL | YK164B | YK164B | YK164C | YK164D | YK184E | YK184G | YK184J | YK224D | YK224E |
Continuous output (kw/kva) | 8.8/11 | 8.8/11 | 10.8/13.5 | 12.8/16 | 18/22.5 | 25/31.3 | 32/40 | 40/50 | 48/60 |
Power efficiency | 79.4% | 79.4% | 80.7% | 81.7% | 84.2% | 86.2% | 87.5% | 88.2% | 88.8% |
Voltage regulation | ±1.0% with 4% engine governing | ||||||||
Waveform distortion | No load Ð1.5% and non-distorting balanced linear load Ð5% | ||||||||
THF/TIF | Ð2%/Ð50 | ||||||||
GFYM7 | GFYM8.5 | GFYM10 | GFYM12 | GFYM16 | GFYM25 | GFYM32 | GFYM40 | GFYM45 | |
Open type dimensions(L/W/H)mm | 1500×600×1070 | 1800×600×1200 | 1850×650×1250 | 2000×750×1300 | |||||
Soundproof type dimensions (L/W/H)mm | 1800×1000×110 | 2300×1100×1160 | 2300×1100×1160 | 2400×1100×1210 | |||||
Fuel tank capacity(L) | 120 | 140 | 140 | 140 |
MAIN SPECIFICATION OF GENERTOR SETS(60HZ) | |||||||||
DIESEL ENGINE MODEL | GF-YM8 | GF-YM10 | GF-YM12 | GF-YM15 | GF-YM20 | GF-YM30 | GF-YM37.5 | EP-GF42 | GF-YM50 |
Continuous output(kw/kva) | 8/10.0 | 10/12.5 | 12/15.0 | 15/18.75 | 20/25 | 30/37.5 | 37.5/46.9 | 42/52.5 | 50/62.5 |
Standby output(kw/kva) | 8.8/11 | 11/13.75 | 13.2/16.5 | 16.5/20.6 | 22/27.5 | 33/42 | 41.25/52 | 46.2/58 | 55/70 |
TECHNICAL DATA(60Hz) | |||||||||
DIESEL ENGINE MODEL | 3TNV76 | 3TNV82A | 3TNV88 | 3TNV84T | 4TNV84T | 4TNV98 | 4TNV98T | 4TNV106 | 4TNV106T |
Engine characters | Vertical type,4-stroke,water cooled,1500RPM | ||||||||
Standby output(KW) | 10.7 | 13.2 | 16.3 | 18.8 | 26.9 | 41.2 | 50.4 | 58.7 | 66.9 |
Aspiration | Natural | Turbo | Turbo | Natural | Turbo | Natural | Turbo | ||
Bore(mm)*stroke(mm) | 76×82 | 82×84 | 88×90 | 84×90 | 84×90 | 98×110 | 98×110 | 106×125 | 106×125 |
NO.of cylinder | 3 | 3 | 3 | 3 | 4 | 4 | 4 | 4 | 4 |
Displacement (lit) | 1.116 | 1.33 | 1.642 | 1.496 | 1.995 | 3.318 | 3.318 | 4.412 | 4.412 |
Cooling system | Radiator | ||||||||
Combustion | IDI | Direct injection | |||||||
Starting System | Electric | ||||||||
ALTERNATOR MODEL | YK164A | YK164B | YK164C | YK164D | YK184E | YK184G | YK184H | YK224C | YK224D |
Continuous output (kw/kva) | 8.2/10.2 | 11/13.8 | 13.5/16.9 | 16/20 | 23/28.8 | 30/37.5 | 37.5/46.9 | 42/52.5 | 50/62.5 |
Power efficiency | 76.2% | 79.4% | 80.7% | 81.7% | 84.2% | 86.2% | 86.3% | 87.8% | 88.2% |
Voltage regulation | ±1.0% with 4% engine governing | ||||||||
Waveform distortion | No load Ð1.5% and non-distorting balanced linear load Ð5% | ||||||||
THF/TIF | Ð2%/Ð50 | ||||||||
GFYM8 | GFYM10 | GFYM12 | GFYM15 | GFYM20 | GFYM30 | GFYM37.5 | GFYM42 | GFYM50 | |
Open type dimensions(L/W/H)mm | 1500×600×1070 | 1800×600×1200 | 1850×650×1250 | 2000×750×1300 | |||||
Soundproof type dimensions (L/W/H)mm | 1800×1000×110 | 2300×1100×1160 | 2300×1100×1160 | 2400×1100×1210 | |||||
Fuel tank capacity(L) | 32 | 38 | 38 | 38 |
In line with our policy of continuous product development ,we reserve the rinht to change specification without notice.